Aeromech builds vertical, horizontal, ceiling-mounted and mobile laminar airflow units at our two factories in Chennai, at Gerugambakkam and Paraniputhur. Every unit uses an H14 HEPA filter and is specified for an ISO 5 work zone.
Labs, pharma units, hospitals and electronics plants across Chennai can inspect a unit at our factory, get it installed by our own technicians, and have it tested and certified by our NABL-accredited team, all from one local company.
Cleanroom Systems Installed
Over Two Decades of Industry Experience
Cleanroom Equipment & Technical Services
Installation, Calibration & Maintenance







A laminar airflow unit, also called a laminar flow clean bench, provides an ISO 5 clean work zone for non-hazardous products and processes. Room air passes through a pre-filter and an H14 HEPA filter, then flows across the work area as a uniform, low-turbulence stream.
Aeromech builds laminar airflow in several forms: vertical units that push filtered air downward onto the work surface, horizontal units that move it from the rear toward the open front, ceiling-mounted units for clean zones over equipment, mobile cart units and PCR workstations.
Aeromech Laminar Airflow units can be considered for non-hazardous applications such as:
A laminar airflow unit protects the product, not the operator. For infectious, toxic or other hazardous materials, use a biosafety cabinet or a fume hood instead.
Choose downward airflow onto the work surface or rear-to-front airflow across it, depending on the process and how equipment sits in the work zone.
Pre-filtration followed by an imported minipleat H14 HEPA filter, rated 99.99% at 0.3 µm, supplies the work zone.
Units are specified for an ISO 5 clean work area as per ISO 14644-1 under the stated operating and test conditions.
Airflow velocity of 0.45 ± 0.05 m/s (90 ± 10 FPM), with differential-pressure indication to show filter condition.
A balanced induction motor and centrifugal blower on Aeromech spring-suspension mounting keeps vibration and noise low (under 67 dBA).
PU-coated GI, satin-finish stainless steel or laminated bodies, an SS304 work surface and glass, acrylic or UV-protected polycarbonate side panels.
Aeromech supplies, installs and services Laminar Airflow across Chennai and nearby industrial areas, including:
Need Laminar Airflow elsewhere in India? See our full Laminar Airflow range.
Registered Office: #3/1760, F-5, Srisudharsan Flat, Bell Nagar, Madanandapuram, Mugaliwakkam, Chennai – 600125 · +91 73586 47600
Factory Unit 1: 7A, Multi Industrial Nagar, Gerugambakkam, Chennai – 600128 · +91 95002 14900
Factory Unit 2: #8/64, Dhanabakiyam Street, Krishnaveni Industrial Estate, Paraniputhur, Chennai – 600122 · +91 94450 64312
Factory visits by appointment: +91 73586 47600
| Specification | Laminar Airflow Information |
|---|---|
| Product range | Vertical, horizontal, ceiling-mounted, mobile cart and PCR workstation models |
| Pre-filter | Micro-glass-fibre media, EU4 rating |
| Final filter | Imported minipleat H14 HEPA filter |
| HEPA efficiency | 99.99% at 0.3 µm |
| Air cleanliness | ISO 5 as per ISO 14644-1 |
| Airflow velocity | 0.45 ± 0.05 m/s (90 ± 10 FPM) |
| Construction | PU-coated GI / satin-finish stainless steel / laminated |
| Work surface | SS304 with reinforcement |
| Side panels | Clear glass / clear acrylic / UV-protected polycarbonate |
| Pressure monitoring | Dwyer Minihelic gauge or Aeromech inclined manometer |
| Lighting | Minimum 800 lux on the work table |
| Noise level | Less than 67 dBA (ambient not above 57 dBA) |
| Electrical | One 15 A three-pin socket, on/off switches with indicators |
| Dimensions | According to the approved drawing |
Depending on the approved model, a standard Laminar Airflow unit includes:
Laminar Airflow is the right choice when the main need is protecting a non-hazardous product or process from airborne particles. If the operator or the room also needs protection, a biosafety cabinet is the safer option.
In and around Chennai, it is used by:
For Chennai orders, our engineers confirm the working size, airflow direction and materials at your site or at our factory. Units are built and tested in Chennai, then installed at your site by our own technicians. After installation, our NABL-accredited team can test airflow velocity, HEPA filter integrity and particle count, and issue the calibration report.
Each Laminar Airflow unit can be configured according to:
Aeromech has installed 3000+ cleanroom systems since 2002, including laminar airflow units for pharma, hospital and research clients with Chennai operations such as Fourrts India, Apollo Hospitals and IIT Madras.
Every Laminar Airflow project in Chennai follows the same six steps, from requirement review at your site to testing and handover.
We review the application, material type, required work area, project location and preferred configuration.
Aeromech recommends a suitable product configuration based on the information provided.
The selected dimensions, materials, components, options and documentation are confirmed before manufacturing.
The cabinet is manufactured and inspected according to the approved product scope.
The product is delivered to the agreed location. Installation and commissioning services can be included where applicable.
Applicable testing, documentation and operator guidance can be provided according to the order scope.
Laminar Airflow price depends on the airflow type, working dimensions, construction material, filter size, side panels, monitoring options, quantity and installation scope.
Find answers to common questions about Laminar Airflow in Chennai
A laminar airflow unit is a clean-work cabinet that passes H14 HEPA-filtered air across the work zone in a uniform stream. It protects non-hazardous products and processes from airborne particles and provides an ISO 5 work area.
Vertical laminar airflow moves filtered air downward onto the work surface. Horizontal laminar airflow moves it from the rear of the cabinet toward the open front. The right choice depends on the process and how equipment sits inside the work zone.
No. A laminar airflow unit is designed for product protection. Work with infectious, toxic or hazardous materials needs a biosafety cabinet or fume-containment equipment.
The standard specification is an airflow velocity of 0.45 ± 0.05 m/s (90 ± 10 FPM) and an ISO 5 work zone as per ISO 14644-1, with an H14 HEPA filter rated 99.99% at 0.3 µm.
Bodies are available in PU-coated galvanised iron, satin-finish stainless steel or laminated construction, with an SS304 work surface and glass, acrylic or UV-protected polycarbonate side panels.
Yes. Aeromech builds vertical, horizontal, ceiling-mounted and mobile cart laminar airflow units and PCR workstations at our Gerugambakkam and Paraniputhur factories in Chennai.
Yes. You can visit our Gerugambakkam or Paraniputhur factory by appointment to check the build, materials and airflow before the unit is dispatched. For appointments, call or WhatsApp +91 73586 47600.
Yes. Our technicians install the unit at your Chennai site, and our NABL-accredited team can test airflow velocity, HEPA filter integrity and particle count and issue the calibration report.
Yes. Our laminar airflow calibration service in Chennai covers units from any manufacturer. Our NABL-accredited team tests downflow velocity, HEPA filter integrity, particle count, light, noise and UV intensity, and issues the calibration report.
We deliver and install across Chennai and nearby areas, including Guindy, Taramani, Sriperumbudur, Oragadam, Maraimalai Nagar, Gummidipoondi, Sri City, Vellore and Puducherry.
We evaluate the intended application, operating environment and technical requirements before recommending equipment configurations.
Established in Chennai in 2002, Aeromech has nearly 24 years of experience in cleanroom equipment manufacturing and contamination control services.
Aeromech provides cleanroom equipment manufacturing alongside validation, calibration and testing services, allowing customers to address related requirements through one company.
Aeromech supplies cleanroom and laboratory equipment across major Indian locations.
Installation, commissioning and applicable performance testing can be included in the project scope.
Maintenance, filter replacement, performance testing and other applicable support are available after installation.
Our dedication to innovation allows us to provide solutions that not only meet but exceed the expectations of our clients.
We trust Aeromech for clean room solutions; their service enhanced our lab’s performance and maintained high cleanliness standards.
Production Head
Aeromech’s clean room engineering service significantly improved our workspace safety and efficiency, providing reliable solutions that meet all our lab requirements.
Chief surgeon