Laminar Airflow Manufacturer in Chennai

Aeromech builds vertical, horizontal, ceiling-mounted and mobile laminar airflow units at our two factories in Chennai, at Gerugambakkam and Paraniputhur. Every unit uses an H14 HEPA filter and is specified for an ISO 5 work zone.

Labs, pharma units, hospitals and electronics plants across Chennai can inspect a unit at our factory, get it installed by our own technicians, and have it tested and certified by our NABL-accredited team, all from one local company.

  • ISO 5 Work Zone
  • H14 HEPA Filter
  • Vertical & Horizontal Models
Vertical laminar Airflow
3000+

Cleanroom Systems Installed

Since 2002

Over Two Decades of Industry Experience

Pan-India Supply

Cleanroom Equipment & Technical Services

Technical Support

Installation, Calibration & Maintenance

What Is Vertical Laminar Airflow

What Is Laminar Airflow?

A laminar airflow unit, also called a laminar flow clean bench, provides an ISO 5 clean work zone for non-hazardous products and processes. Room air passes through a pre-filter and an H14 HEPA filter, then flows across the work area as a uniform, low-turbulence stream.

Aeromech builds laminar airflow in several forms: vertical units that push filtered air downward onto the work surface, horizontal units that move it from the rear toward the open front, ceiling-mounted units for clean zones over equipment, mobile cart units and PCR workstations.

How Laminar Airflow Works?

  • Room air enters through the air intake.
  • The pre-filter (EU4 micro-glass-fibre) captures larger particles.
  • The H14 HEPA filter removes 99.99% of particles at 0.3 µm.
  • Filtered air enters the work zone vertically or horizontally, depending on the model.
  • Air sweeps across the work surface at 0.45 ± 0.05 m/s.
  • The continuous flow keeps the work zone at ISO 5.

Laminar Airflow Applications

Aeromech Laminar Airflow units can be considered for non-hazardous applications such as:

  • Tissue and plant-cell culture
  • Sterility-related work
  • Non-hazardous pharmaceutical preparation
  • Vial filling and bunging
  • Microbiology with non-hazardous materials
  • Electronics and semiconductor assembly
  • Medical-device assembly
  • Assembly of miniature mechanisms
  • Food-industry clean processes
  • Research and development
  • Quality-control laboratories
  • General clean product handling

A laminar airflow unit protects the product, not the operator. For infectious, toxic or other hazardous materials, use a biosafety cabinet or a fume hood instead.

Laminar Airflow Features

Vertical or Horizontal Airflow

Choose downward airflow onto the work surface or rear-to-front airflow across it, depending on the process and how equipment sits in the work zone.

H14 HEPA Filtration

Pre-filtration followed by an imported minipleat H14 HEPA filter, rated 99.99% at 0.3 µm, supplies the work zone.

ISO 5 Work Zone

Units are specified for an ISO 5 clean work area as per ISO 14644-1 under the stated operating and test conditions.

Controlled Air Velocity

Airflow velocity of 0.45 ± 0.05 m/s (90 ± 10 FPM), with differential-pressure indication to show filter condition.

Low-Vibration Blower

A balanced induction motor and centrifugal blower on Aeromech spring-suspension mounting keeps vibration and noise low (under 67 dBA).

Custom Construction

PU-coated GI, satin-finish stainless steel or laminated bodies, an SS304 work surface and glass, acrylic or UV-protected polycarbonate side panels.

Service Area

Laminar Airflow Supply Across Chennai & Nearby Areas

Aeromech supplies, installs and services Laminar Airflow across Chennai and nearby industrial areas, including:

  • Ambattur
  • Guindy
  • Perungudi
  • Taramani
  • Sriperumbudur
  • Oragadam
  • Irungattukottai
  • Maraimalai Nagar
  • Gummidipoondi
  • Sri City
  • Ranipet
  • Vellore
  • Puducherry

Need Laminar Airflow elsewhere in India? See our full Laminar Airflow range.

Registered Office: #3/1760, F-5, Srisudharsan Flat, Bell Nagar, Madanandapuram, Mugaliwakkam, Chennai – 600125 · +91 73586 47600

Factory Unit 1: 7A, Multi Industrial Nagar, Gerugambakkam, Chennai – 600128 · +91 95002 14900

Factory Unit 2: #8/64, Dhanabakiyam Street, Krishnaveni Industrial Estate, Paraniputhur, Chennai – 600122 · +91 94450 64312

Factory visits by appointment: +91 73586 47600

Laminar Airflow Specifications & Options

SpecificationLaminar Airflow Information
Product rangeVertical, horizontal, ceiling-mounted, mobile cart and PCR workstation models
Pre-filterMicro-glass-fibre media, EU4 rating
Final filterImported minipleat H14 HEPA filter
HEPA efficiency99.99% at 0.3 µm
Air cleanlinessISO 5 as per ISO 14644-1
Airflow velocity0.45 ± 0.05 m/s (90 ± 10 FPM)
ConstructionPU-coated GI / satin-finish stainless steel / laminated
Work surfaceSS304 with reinforcement
Side panelsClear glass / clear acrylic / UV-protected polycarbonate
Pressure monitoringDwyer Minihelic gauge or Aeromech inclined manometer
LightingMinimum 800 lux on the work table
Noise levelLess than 67 dBA (ambient not above 57 dBA)
ElectricalOne 15 A three-pin socket, on/off switches with indicators
DimensionsAccording to the approved drawing
Need a customised Laminar Airflow ?
Let us know your requirements

Standard components

Depending on the approved model, a standard Laminar Airflow unit includes:

  • Cabinet body or stand-mounted frame
  • SS304 work surface
  • Pre-filter
  • H14 HEPA filter
  • Motor-blower assembly
  • Spring-suspension mounting
  • Transparent side panels
  • Differential-pressure indication
  • Work-area lighting
  • Electrical socket
  • On/off controls with indicators
  • Optional UV light, hour meter, alarm and air-velocity display

Is Laminar Airflow Right for Your Chennai Facility?

Laminar Airflow is the right choice when the main need is protecting a non-hazardous product or process from airborne particles. If the operator or the room also needs protection, a biosafety cabinet is the safer option.

In and around Chennai, it is used by:

  • Pharma QC and microbiology labs
  • Sterile preparation in hospital pharmacies
  • IVF and tissue-culture labs
  • Biotech labs in Taramani
  • Electronics assembly in Sriperumbudur
  • Medical-device units in Oragadam
  • University and IIT Madras research labs
  • Food and nutraceutical QC
  • Diagnostic and pathology labs
Vertical Laminar Airflow Manufacturer

Customised Laminar Airflow Projects in Chennai

For Chennai orders, our engineers confirm the working size, airflow direction and materials at your site or at our factory. Units are built and tested in Chennai, then installed at your site by our own technicians. After installation, our NABL-accredited team can test airflow velocity, HEPA filter integrity and particle count, and issue the calibration report.

Each Laminar Airflow unit can be configured according to:

  • Required working dimensions
  • Vertical or horizontal airflow
  • Cabinet construction material
  • Side-panel material
  • Pressure-monitoring arrangement
  • Utility nozzle positions
  • Optional UV arrangement
  • Air-velocity indication
  • Electrical requirements
  • Installation space

Aeromech has installed 3000+ cleanroom systems since 2002, including laminar airflow units for pharma, hospital and research clients with Chennai operations such as Fourrts India, Apollo Hospitals and IIT Madras.

Our workflow

How We Supply Laminar Airflow in Chennai

Every Laminar Airflow project in Chennai follows the same six steps, from requirement review at your site to testing and handover.

Looking for a customised solution?

Laminar Airflow Price in Chennai

Laminar Airflow price depends on the airflow type, working dimensions, construction material, filter size, side panels, monitoring options, quantity and installation scope.

Starting From
3 Lakh
onwards
Factors affecting the Laminar Airflow price
  • Vertical or horizontal model
  • Working-area dimensions
  • PU-coated GI, stainless-steel or laminated body
  • HEPA filter size and quantity
  • Side-panel material
  • Pressure gauge or air-velocity monitor
  • UV light and hour meter
  • Alarm requirements
  • Number of units
  • Installation and testing scope

Frequently Asked Questions

Find answers to common questions about Laminar Airflow in Chennai

A laminar airflow unit is a clean-work cabinet that passes H14 HEPA-filtered air across the work zone in a uniform stream. It protects non-hazardous products and processes from airborne particles and provides an ISO 5 work area.

Vertical laminar airflow moves filtered air downward onto the work surface. Horizontal laminar airflow moves it from the rear of the cabinet toward the open front. The right choice depends on the process and how equipment sits inside the work zone.

No. A laminar airflow unit is designed for product protection. Work with infectious, toxic or hazardous materials needs a biosafety cabinet or fume-containment equipment.

The standard specification is an airflow velocity of 0.45 ± 0.05 m/s (90 ± 10 FPM) and an ISO 5 work zone as per ISO 14644-1, with an H14 HEPA filter rated 99.99% at 0.3 µm.

Bodies are available in PU-coated galvanised iron, satin-finish stainless steel or laminated construction, with an SS304 work surface and glass, acrylic or UV-protected polycarbonate side panels.

Yes. Aeromech builds vertical, horizontal, ceiling-mounted and mobile cart laminar airflow units and PCR workstations at our Gerugambakkam and Paraniputhur factories in Chennai.

Yes. You can visit our Gerugambakkam or Paraniputhur factory by appointment to check the build, materials and airflow before the unit is dispatched. For appointments, call or WhatsApp +91 73586 47600.

Yes. Our technicians install the unit at your Chennai site, and our NABL-accredited team can test airflow velocity, HEPA filter integrity and particle count and issue the calibration report.

Yes. Our laminar airflow calibration service in Chennai covers units from any manufacturer. Our NABL-accredited team tests downflow velocity, HEPA filter integrity, particle count, light, noise and UV intensity, and issues the calibration report.

We deliver and install across Chennai and nearby areas, including Guindy, Taramani, Sriperumbudur, Oragadam, Maraimalai Nagar, Gummidipoondi, Sri City, Vellore and Puducherry.

Why choose Aeromech?

Application-Based Engineering

We evaluate the intended application, operating environment and technical requirements before recommending equipment configurations.

Experience Since 2002

Established in Chennai in 2002, Aeromech has nearly 24 years of experience in cleanroom equipment manufacturing and contamination control services.

Manufacturing & Services

Aeromech provides cleanroom equipment manufacturing alongside validation, calibration and testing services, allowing customers to address related requirements through one company.

Pan-India supply

Aeromech supplies cleanroom and laboratory equipment across major Indian locations.

Installation and testing support

Installation, commissioning and applicable performance testing can be included in the project scope.

After-sales service

Maintenance, filter replacement, performance testing and other applicable support are available after installation.

We're Ready to Hear From You:)

What our Customers Say?

Our dedication to innovation allows us to provide solutions that not only meet but exceed the expectations of our clients.

Chat with us on WhatsApp