Aeromech supplies vertical, horizontal, ceiling-mounted and mobile laminar airflow units to Ahmedabad, built and factory-tested at our own manufacturing units and installed on site by our own technicians. Every unit uses an H14 HEPA filter, is specified for an ISO 5 work zone and runs at 0.45 ± 0.05 m/s airflow velocity.
We supply and support customers in the formulation hub around Changodar and Sanand and the API and chemical belt from Vadodara to Ankleshwar, Dahej and Vapi. Our NABL-accredited team travels to Ahmedabad to calibrate each unit after installation, and we offer annual maintenance contracts across the region.
Cleanroom Systems Installed
Over Two Decades of Industry Experience
Cleanroom Equipment & Technical Services
Installation, Calibration & Maintenance







A laminar airflow unit, also called a laminar flow clean bench, provides an ISO 5 clean work zone for non-hazardous products and processes. Room air passes through a pre-filter and an H14 HEPA filter, then flows across the work area as a uniform, low-turbulence stream.
Aeromech builds laminar airflow in several forms: vertical units that push filtered air downward onto the work surface, horizontal units that move it from the rear toward the open front, ceiling-mounted units for clean zones over equipment, mobile cart units and PCR workstations.
Aeromech Laminar Airflow units can be considered for non-hazardous applications such as:
A laminar airflow unit protects the product, not the operator. For infectious, toxic or other hazardous materials, use a biosafety cabinet or a fume hood instead.
Choose downward airflow onto the work surface or rear-to-front airflow across it, depending on the process and how equipment sits in the work zone.
Pre-filtration followed by an imported minipleat H14 HEPA filter, rated 99.99% at 0.3 µm, supplies the work zone.
Units are specified for an ISO 5 clean work area as per ISO 14644-1 under the stated operating and test conditions.
Airflow velocity of 0.45 ± 0.05 m/s (90 ± 10 FPM), with differential-pressure indication to show filter condition.
A balanced induction motor and centrifugal blower on Aeromech spring-suspension mounting keeps vibration and noise low (under 67 dBA).
PU-coated GI, satin-finish stainless steel or laminated bodies, an SS304 work surface and glass, acrylic or UV-protected polycarbonate side panels.
Aeromech supplies, installs and services Laminar Airflow across Ahmedabad and nearby industrial areas, including:
Need Laminar Airflow elsewhere in India? See our full Laminar Airflow range.
Manufactured in-house: Every unit is built and factory-tested at our own manufacturing units. Road delivery to Ahmedabad takes 6–8 working days.
On-site support in Ahmedabad: Installation, NABL-accredited testing and annual maintenance contracts by our own team.
Sales and site visits: +91 73586 47600 · sales@aeromech.in
| Specification | Laminar Airflow Information |
|---|---|
| Product range | Vertical, horizontal, ceiling-mounted, mobile cart and PCR workstation models |
| Pre-filter | Micro-glass-fibre media, EU4 rating |
| Final filter | Imported minipleat H14 HEPA filter |
| HEPA efficiency | 99.99% at 0.3 µm |
| Air cleanliness | ISO 5 as per ISO 14644-1 |
| Airflow velocity | 0.45 ± 0.05 m/s (90 ± 10 FPM) |
| Construction | PU-coated GI / satin-finish stainless steel / laminated |
| Work surface | SS304 with reinforcement |
| Side panels | Clear glass / clear acrylic / UV-protected polycarbonate |
| Pressure monitoring | Dwyer Minihelic gauge or Aeromech inclined manometer |
| Lighting | Minimum 800 lux on the work table |
| Noise level | Less than 67 dBA (ambient not above 57 dBA) |
| Electrical | One 15 A three-pin socket, on/off switches with indicators |
| Dimensions | According to the approved drawing |
Depending on the approved model, a standard Laminar Airflow unit includes:
Laminar Airflow is the right choice when the main need is protecting a non-hazardous product or process from airborne particles. If the operator or the room also needs protection, a biosafety cabinet is the safer option.
In and around Ahmedabad, it is used by:
For Ahmedabad orders, our engineers confirm the size, configuration and site details by drawing, video call or a site visit. Every unit is built and factory-tested at our own manufacturing units, and road delivery to Ahmedabad takes 6–8 working days, depending on size and quantity. Our own technicians travel to Ahmedabad to install and commission each unit, and our NABL-accredited team tests airflow velocity, HEPA filter integrity and particle count on site and issues the calibration report. Annual maintenance contracts cover periodic testing, filter replacement and breakdown support.
Each Laminar Airflow unit can be configured according to:
Aeromech has installed 3000+ cleanroom systems since 2002, including laminar airflow units for pharma, hospital and research labs across India. Our testing laboratory is NABL accredited.
Every Laminar Airflow project in Ahmedabad follows the same six steps, from requirement review at your site to testing and handover.
We review the application, material type, required work area, project location and preferred configuration.
Aeromech recommends a suitable product configuration based on the information provided.
The selected dimensions, materials, components, options and documentation are confirmed before manufacturing.
The cabinet is manufactured and inspected according to the approved product scope.
The product is delivered to the agreed location. Installation and commissioning services can be included where applicable.
Applicable testing, documentation and operator guidance can be provided according to the order scope.
Laminar Airflow price depends on the airflow type, working dimensions, construction material, filter size, side panels, monitoring options, quantity and installation scope.
Find answers to common questions about Laminar Airflow in Ahmedabad
A laminar airflow unit is a clean-work cabinet that passes H14 HEPA-filtered air across the work zone in a uniform stream. It protects non-hazardous products and processes from airborne particles and provides an ISO 5 work area.
Vertical laminar airflow moves filtered air downward onto the work surface. Horizontal laminar airflow moves it from the rear of the cabinet toward the open front. The right choice depends on the process and how equipment sits inside the work zone.
No. A laminar airflow unit is designed for product protection. Work with infectious, toxic or hazardous materials needs a biosafety cabinet or fume-containment equipment.
The standard specification is an airflow velocity of 0.45 ± 0.05 m/s (90 ± 10 FPM) and an ISO 5 work zone as per ISO 14644-1, with an H14 HEPA filter rated 99.99% at 0.3 µm.
Bodies are available in PU-coated galvanised iron, satin-finish stainless steel or laminated construction, with an SS304 work surface and glass, acrylic or UV-protected polycarbonate side panels.
Yes. Aeromech supplies vertical, horizontal, ceiling-mounted and mobile laminar airflow units to Ahmedabad, built in our own manufacturing units and installed on site by our own technicians.
Road delivery to Ahmedabad takes 6–8 working days after dispatch, depending on the size and number of units. Manufacturing time is confirmed with the quotation.
Yes. Our technicians travel to Ahmedabad to install and commission each unit, and our NABL-accredited team tests airflow velocity, HEPA filter integrity and particle count on site and issues the calibration report.
Yes. Our AMCs in Ahmedabad cover periodic recalibration, filter replacement and breakdown support for laminar airflow units.
We supply and support customers across Ahmedabad and nearby industrial areas, including Changodar, Sanand, Vatva, Vadodara, Ankleshwar, Dahej and Vapi.
We evaluate the intended application, operating environment and technical requirements before recommending equipment configurations.
Established in Chennai in 2002, Aeromech has nearly 24 years of experience in cleanroom equipment manufacturing and contamination control services.
Aeromech provides cleanroom equipment manufacturing alongside validation, calibration and testing services, allowing customers to address related requirements through one company.
Aeromech supplies cleanroom and laboratory equipment across major Indian locations.
Installation, commissioning and applicable performance testing can be included in the project scope.
Maintenance, filter replacement, performance testing and other applicable support are available after installation.
Our dedication to innovation allows us to provide solutions that not only meet but exceed the expectations of our clients.
We trust Aeromech for clean room solutions; their service enhanced our lab’s performance and maintained high cleanliness standards.
Production Head
Aeromech’s clean room engineering service significantly improved our workspace safety and efficiency, providing reliable solutions that meet all our lab requirements.
Chief surgeon